Works on system of ignition
Ignition stop
The control unit and the terminal cascade inevitably fail if the engine is turned by a starter at the disconnected wire of high voltage. Therefore:
|
- 74 kW engine: disconnect the socket on the terminal cascade (near the ignition coil) at the switched-off ignition.
- 92 kW engine: uncover the engine and disconnect the socket on the terminal cascade of power in a package of coils of ignition.
- 110 kW four-cylinder engine and six-cylinder engine: disconnect both sockets on the terminal cascade (under a cover) at the switched-off ignition.
|
|
|