Check of idling and exhaust gases
At system of ignition/injection Motronic adjusting works are not carried out as this self-training system. It means that the control unit corrects if it is necessary, idling speed. For turns of idling the following control sizes work (check conditions: the engine is heated-up, all consumers of the electric power are disconnected, and the moment of ignition is determined correctly):
Idling speed: 820–900 rpm.
Contents WITH cannot be measured in exhaust gases in front of the catalytic converter. Therefore recheck is possible only by means of the device for reading of the computer.
|